On line monitoring system for insulator pollution of transmission line

Composition introduction

Pollution collector, GPRS / wireless data terminal and management master station

technical parameter

Pollution current measurement range: 0 —— 50mA;

Pollution current accuracy: ± 10uA (less than 1mA) or 1% (more than 1mA);

Number of discharge recording and broadcasting points: no less than 80;

Wireless communication distance: no less than 50m;

Static power consumption of collector: 15ua / 3.6V (excluding power consumption of wireless communication, operation lamp and alarm lamp);

Static power consumption of terminal: 30uA / 3.6V (excluding GPRS communication);

Number of measuring points: 3 phases;

Ambient temperature measurement accuracy: ± 1%

Environmental humidity measurement accuracy: ± 3%;

Service life: ≥ 8 years;

work environment

Relative humidity: ≤ 99%;

Adaptive altitude: < 3000m;

Temperature: - 40 ℃ —— + 70 ℃.

Technical characteristicsThe collector is directly installed on the insulator and adopts a new type of cut-off ring design. The sampling resistance is added to the sampling circuit to improve the anti-interference ability and ensure the sampling accuracy;

All the components of the product are industrial devices, which ensure the high reliability of the product, and the product design indexes meet the requirements of industrial outdoor products;

Multiple power supply modes:

8.5ah disposable lithium battery;

Lithium iron phosphate rechargeable battery;

Multiple solar panels;

With the function of recording discharge pulse current, it can show the discharge pulse current to the operation and maintenance personnel, and provide detailed original data for fault diagnosis;

The short-distance wireless communication mode is adopted between the pollution collector and the terminal for information exchange, and the cable connection is canceled to avoid the electromagnetic interference caused by too long cable;

The main station system server can receive, store and display the comparison curve between pollution current and ambient temperature and humidity, and the waveform of discharge pulse recorder, etc. to make qualitative and quantitative analysis and trend prediction of pollution current of insulator in operation;

The recording of discharge pulse can record the waveform of 100ms before and after the occurrence of the pulse. The format of the recording file follows the format defined in COMTRADE 1999 standard.